When this happens, the furnace will no longer light. The limit switch may be bad and need to be replaced. It could be something as simple as a broken valve, or it could be something more serious. A layer of grime will block the oxygen necessary to allow the burner to ignite.
It is tempting to try and save a few dollars with a DIY home furnace repair. Situation: You turn the thermostat up, the furnace ignites and the burner comes on. Check the electrical panel to see if there is a tripped breaker and reset it. It is important to make sure the switch on the door is properly engaged. However, when you attempt to switch on your heating, you notice that your furnace ignitor isn't igniting. Then, remove the front panel to find the ignitor or ignition sensor. Control board malfunction: The control board is the brain and central switching station for the furnace, containing the relays and circuits that operate the furnace. Furnace burners not igniting. Flash codes are a series of light "blips" using one or two lights. Your furnace won't ignite due to one or more of the following reasons: 1. In most cases of furnace burner failure, you should never attempt to solve the problem on your own. If your furnace is not turning on you should first check if the filter is clean.
Reset The Furnace Ignitor. However, if you enjoy DIY, find the high limit switch. The gas valve sends gas to the main burner(s), which is lit by the pilot light. On most newer gas furnaces with an integrated control board, a pressure switch fault will generate a diagnostic code - usually a code 2 or 3, but it varies with the board manufacturer. 6 Reasons Why Your Furnace Won’t Ignite. Faulty flame sensor. Do the stove top and other LP appliances work correctly? The difference between the two is that the pilot flame in the intermittent pilot igniter comes on only when the thermostat signals the heat to turn on. If the burner won't ignite, the furnace will not generate heat, and you'll only receive room temperature air from your vents.
There are a few reasons why a furnace burner will not stay lit, and while you should not attempt to repair a malfunctioning furnace burner on your own, it is helpful to understand why it can happen. We're in the middle of the cold season, which makes your gas furnace the most important appliance in your home. If the flame sensor is clean but the burners still shut off around 6 seconds after ignition, this may be the result of a faulty ignition control. A direct ignition furnace has a flame sensor over the burner that shuts off the gas if it doesn't sense a flame. The Furnace is Turned Off. Furnace will not light. Typically found in induced draft furnaces, an intermittent pilot ignites the burner gas with a high-voltage spark only when the thermostat calls for heat. If power surges are frequent they can cause the ignitor to burn out especially in hot surface ignition systems due to the burning filaments they use. Because of this, the furnace won't run, to prevent the risk of overflowing. The combination of electronic ignition, electronic controls, and artificially created draft improves the efficiency of induced draft furnaces over older conventional models. There is a power disconnect switch by the furnace. You've got questions, we've got answers. Look under your furnace to see if it's lit. First of all, you need to go out into your yard and locate where your gas storage tank is.
These resources might help you in troubleshooting a furnace that won't start / won't ignite. It can be difficult for homeowners to tell when a replacement is needed as it requires testing the ignitor using a multimeter. To find out, it's a good idea to check the gas supply to your home to see if it's working. 3 Reasons Why Your Furnace Won’t Ignite | Cowboy's Air Conditioning & Heating. See the FAQ Section below for igniter cleaning step-by-step directions. The power switch on the furnace is in the ON position. To troubleshoot the problem, you first need to understand how your furnace ignition system works. There Is An Issue With Your Thermostat. If you suspect that this may be the problem an HVAC technician can do this for you.
It may take a few minutes to start running even after being lit, so be patient. This can happen sooner if the oils from your skin get on the element through improper handling, so take care not to touch the element with your bare hands. However, a lot of furnace owners fail to do this. If it has been tripped, be sure to turn it back on. Call Skylands Energy Service For All Of Your Furnace Repair Requirements. Check Your Air Filters. When Your Gas Furnace Ignitor Is Not Working, Call The HVAC Experts At Service. One of the most common problems that occur with a gas furnace is an electronic ignition failure. The following steps are usually part of a regular furnace maintenance checks to help keep your system working efficiently. This means that over time, it will start to lose functionality until it no longer functions properly. For the burners to ignite, they need airflow. Previously, gas furnaces had pilot lights for operation where the light would stay on if the furnace was operating correctly. First, you need to turn off the gas in the furnace. This is most likely to happen with the filaments that carry the warming electricity in the hot surface ignitor.
They're also called fault codes. It ignited, burned, and brought heat to the home. OK, three quick things that might be the problem if you're new to the house or the HVAC system was worked on immediately before it won't work. Other reasons it won't start can stem from improper thermostat settings, forgetting to turn on the gas line, or faulty pilot light. Furnace won't light the burners keep. Blown fuse/tripped circuit breaker: Modern gas furnaces do not run entirely on natural gas. What's the easiest way to tell you to have a defective thermostat? How a Furnace Works.
Another easy way to tell if the gas is on and working properly is by starting another gas-burning appliance, like the stove. Fortunately, there's a solution to your problem. This system is more reliable and safer than old conventional furnaces, which relied on a natural draft coming in from an opening at the front of the furnace. Where is My Air Filter Located? If those items get really dusty, use a shop vacuum with a brush head to gently remove the dust. You can then turn the power source back on and restart the furnace. Hi there, thanks for the question.
Follow these steps to fix a gas furnace that won't ignite: - Ensure the furnace filter is clean—if not, replace the dirty filter with a clean filter. Have an HVAC technician replace the flame sensor. If this gas pressure gauge reads 10% or above, then you should be OK; if not, call your gas company for a fill-up, and you have probably solved the reason why your furnace did not start up. This calls for immediate professional help from your HVAC company. The flames from the burners may be going out because they're struggling to draw enough oxygen for combustion through excess dirt or other grime along their surface. If it still doesn't work, after you have tried all of those options, the problem is probably slightly more tricky than a simple thermostat fix. Bookmark the page, and when the time comes, click to our In-depth Thermostat Wiring Guide for Homeowners for 3 Simple Methods to Wire a Thermostat. Call an HVAC professional to check it out. How much is a service call? If the flame sensor malfunctions, it will mistakenly sense the burners haven't ignited and shut the gas off anyway, causing the burners to go out.
Knowing how to detect the problem can help you decide when you need to call in an HVAC contractor. By the way, we should ask you if you've recently replaced your standard air filter with a high-MERV filter, like a MERV 12 or higher? If this happens, hopefully, the tips above will help you to determine what the problem is without too much stress. It depends on the age of your furnace and how frequently you've had to make furnace repairs to determine whether a new furnace installation is in order. Unless you're sure of what something does, don't touch it. A high-limit switch trip caused by no airflow (bad blower) will typically occur within 30-60 seconds after ignition. A thermocouple is a safety component that uses two different types of metal wire to measure the temperature of the flame.
Contact a professional to remove, clean, and return the burners. The HSI heats up to around 1, 800 to 2, 500 degrees Fahrenheit and glows red-hot. Before attempting to reset the ignitor, make sure the power source for it has been turned off by flipping the circuit switch. Like any type of mechanical appliance, they are prone to occasional breakdowns. Call now or click on the button below to schedule a service today. A filter clogged with dirt may make the switch think temperatures are getting too high. Solution: If the draft motor doesn't come on, be suspicious that it might be the cause of your trouble. Why Won't My Furnace Ignite? If it is getting power but won't light, it is bad. There are multiple potential problems that your furnace could be having. The intermittent pilot igniter is one kind of electronic ignition system.